Petitcodiac School Energy Audit And Final Report
Summary
Heat loss: 76,449 btu per year
Investment: $4,582
Payback Period: 1.2 years
ROI Rate: 83.1%
20-year Net Present Value: $71,558
Co2 Emission Savings: 14.73 Mt per year
Beaverbrook School Energy Audit And Final Report
Summary
Heat loss: 50,793 btu per year
Investment: $6,135
Payback Period: 1 year
ROI Rate: 96.4%
20-year Net Present Value: $112,125
Co2 Emission Savings: 28.38 Mt per year
Birchmount School Energy Audit And Final Report
Summary
Heat loss: 35,387 btu per year
Investment: $4,880
Payback Period: 1.2 year
ROI Rate: 81.8%
20-year Net Present Value: $74,920
Co2 Emission Savings: 18.68 Mt per year
JMA Armstrong School Energy Audit And Final Report
Summary
Heat loss: 138,271 Kbtu per year
Investment: $2,769
Payback Period: 0.4 year
ROI Rate: 231%
20-year Net Present Value: $125,151
Co2 Emission Savings: 27.93 Mt per year
King Street Elementary School Final Energy Audit Report
Summary
Heat loss: 138,271 btu per year
Investment: $7,740
Payback Period: 2.5 years
ROI Rate: 39.3%
20-year Net Present Value: $53,120
Co2 Emission Savings: 6.2 Mt per year
NIA Study On Mechanical Insulation In Schools
Summary
This white paper study focuses on quantifying the use of mechanical insulation in schools and hospitals. The study highlights the importance of mechanical insulation in commercial buildings. On average, schools in the study with ASHRAE rated mechanical insulation realized a 0.7 percent energy savings. The entire study can be downloaded and reviewed for best practices in schools.
North/South Esk Regional & North/South Esk Elementary Schools Final Energy Audit Report
Summary
NSER
Heat loss: 2,392 Btu per day
Investment: $7,740
Payback Period: 2.5 years
ROI Rate: 39.3%
20-year Net Present Value: $53,120
Co2 Emission Savings: 1.95 Mt per year
NSEE
Heat loss: 140,448 Btu per day
Investment: $3,405
Payback Period: 1.6 years
ROI Rate: 63.4%
20-year Net Present Value: $39,775
Co2 Emission Savings: 9.95 Mt per year
South Suburban College Final Energy Audit Report
Summary
Heat loss: 207,847 Btu/h
Investment: $38,000
Payback Period: 5.6 years
ROI Rate: 19.9%
20-year Net Present Value: $143,079
Co2 Emission Savings: 78.13 Mt per year
University Of The Fraser Valley Final Energy Audit
Summary
Heat loss: 106,919 Btu/h
Investment: $38,000
Payback Period: 2.1 years
Co2 Emission Savings: 33.6 Mt per year
Lewisville Middle School Final Energy Audit Report
Summary
Heat loss: 154,629 Kbtu per year
Investment: $8,325
Payback Period: 1.8 years
ROI Rate: 54.6%
20-year Net Present Value: $82,615
Co2 Emission Savings: 9.39 Mt per year
Marshview Middle School Final Energy Audit Report
Summary
Heat loss: 255,168 Kbtu per year
Investment: $12,127
Payback Period: 1.6 years
ROI Rate: 62.1%
20-year Net Present Value: $138,413Co2 Emission Savings: 14.79 Mt per year
Millidgeville North School Final Energy Audit Report
Summary
Heat loss: 862,146 Kbtu per year
Investment: $12,127
Payback Period: 1.3 years
ROI Rate: 76.9%
20-year Net Present Value: $720,178
Co2 Emission Savings: 58 Mt per year
Simonds High School Final Energy Audit Report
Summary
Heat loss: 2,348,299 Kbtu per year
Investment: $12,127
Payback Period: 0.7 years
ROI Rate: 135.7%
20-year Net Present Value: $1,261,220
Co2 Emission Savings: 137 Mt per year
Academie Assomption School Report Final Energy Audit Report
Summary
Investment: $61,028
Payback Period: 0.6 years
ROI Rate: 166.3%
20-year Net Present Value: $1,968,852
Co2 Emission Savings: 329.16 Mt per year
Claude D Taylor Final Energy Audit Report
Summary
Investment: $5,376
Payback Period: 0.9 years
ROI Rate: 110.5%
20-year Net Present Value: $113,464
Co2 Emission Savings: 14.18 Mt per year
Ecole Le Croisée Final Energy Audit Report
Summary
Investment: $4,752
Payback Period: 3.6years
ROI Rate: 57.5%
20-year Net Present Value: $21,628
Co2 Emission Savings: 3.7 Mt per year
Ecole Le Tournesol Final Energy Audit Report
Summary
Investment: $7,806
Payback Period: 1.3 years
ROI Rate: 74.3%
20-year Net Present Value: $108,234
Co2 Emission Savings: 18.06 Mt per year
Ecole Marie Esther Final Energy Audit Report
Summary
Investment: $29,174
Payback Period: 0.6 years
ROI Rate: 156.1%
20-year Net Present Value: $881,746
Co2 Emission Savings: 148.82 Mt per year
Ecole Secondaire Nepisiguit Final Energy Audit Report
Summary
Investment: $30,485
Payback Period: 0.5 years
ROI Rate: 185.8%
20-year Net Present Value: $1,102,035
Co2 Emission Savings: 180.76 Mt per year
Florenceville Middle School Final Energy Audit Report
Summary
Investment: $17,376
Payback Period: 1.7 years
ROI Rate: 59%
20-year Net Present Value: $187,824
Co2 Emission Savings: 36.21 Mt per year
Frank L Bowser Final Energy Audit Report
Summary
Investment: $6,141
Payback Period: 1.2 years
ROI Rate: 84.4%
20-year Net Present Value: $97,559
Co2 Emission Savings: 12.24 Mt per year
Hampton High Final Energy Audit Report
Summary
Often times, a poorly performed mechanical insulation energy audit will focus on the mechanical system and ignore obvious things, such as hot water tanks. This expertly performed mechanical insulation energy audit discovered Hampton High School was losing quite a bit of energy around hot water tanks. By adding mechanical insulation to the tanks and their pipes, the school could save over $3,600 in five years.
Harvey High Final Energy Audit Report
Summary
Investment: $1,959
Payback Period: 2.1 years
ROI Rate: 47%
20-year Net Present Value: $16,461
Co2 Emission Savings: 4.42 Mt per year
Kennebecasis Valley Final Energy Audit Report
Summary
Investment: $8,790
Payback Period: 0.5 years
ROI Rate: 198%
20-year Net Present Value: $339,330
Co2 Emission Savings: 50.18 Mt per year
McAdam High Final Energy Audit Report
Summary
Investment: $2,712
Payback Period: 5.2 years
ROI Rate: 18.4%
20-year Net Present Value: $7,628
Co2 Emission Savings: 2.25 Mt per year